rrdtool                                              RRDCREATE(1)



NNNNAAAAMMMMEEEE
     rrdtool create - Set up a new Round Robin Database

SSSSYYYYNNNNOOOOPPPPSSSSIIIISSSS
     rrrrrrrrddddttttoooooooollll ccccrrrreeeeaaaatttteeee _f_i_l_e_n_a_m_e [--------ssssttttaaaarrrrtttt|----bbbb _s_t_a_r_t _t_i_m_e]
     [--------sssstttteeeepppp|----ssss _s_t_e_p] [DDDDSSSS::::_d_s_-_n_a_m_e::::_D_S_T::::_h_e_a_r_t_b_e_a_t::::_m_i_n::::_m_a_x]
     [RRRRRRRRAAAA::::_C_F::::_x_f_f::::_s_t_e_p_s::::_r_o_w_s]

DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN
     The create function of the RRDtool lets you set up new Round
     Robin Database (RRRRRRRRDDDD) files.  The file is created at its
     final, full size and filled with _*_U_N_K_N_O_W_N_* data.

     _f_i_l_e_n_a_m_e
             The name of the RRRRRRRRDDDD you want to create. RRRRRRRRDDDD files
             should end with the extension _._r_r_d. However, rrrrrrrrddddttttoooooooollll
             will accept any filename.

     --------ssssttttaaaarrrrtttt|----bbbb _s_t_a_r_t _t_i_m_e (default: now - 10s)
             Specifies the time in seconds since 1970-01-01 UTC
             when the first value should be added to the RRRRRRRRDDDD.
             rrrrrrrrddddttttoooooooollll will not accept any data timed before or at
             the time specified.

             See also AT-STYLE TIME SPECIFICATION section in the
             _r_r_d_f_e_t_c_h documentation for more ways to specify
             time.

     --------sssstttteeeepppp|----ssss _s_t_e_p (default: 300 seconds)
             Specifies the base interval in seconds with which
             data will be fed into the RRRRRRRRDDDD.

     DDDDSSSS::::_d_s_-_n_a_m_e::::_D_S_T::::_h_e_a_r_t_b_e_a_t::::_m_i_n::::_m_a_x
             A single RRRRRRRRDDDD can accept input from several data
             sources (DDDDSSSS).  (e.g. Incoming and Outgoing traffic
             on a specific communication line). With the DDDDSSSS
             configuration option you must define some basic
             properties of each data source you want to use to
             feed the RRRRRRRRDDDD.

             _d_s_-_n_a_m_e is the name you will use to reference this
             particular data source from an RRRRRRRRDDDD. A _d_s_-_n_a_m_e must
             be 1 to 19 characters long in the characters [a-zA-
             Z0-9_].

             _D_S_T defines the Data Source Type. See the section on
             "How to Measure" below for further insight.  The
             Datasource Type must be onw of the following:

             GGGGAAAAUUUUGGGGEEEE
                 is for things like temperatures or number of
                 people in a room or value of a RedHat share.



2001-02-20             Last change: 1.0.33                      1






rrdtool                                              RRDCREATE(1)



             CCCCOOOOUUUUNNNNTTTTEEEERRRR
                 is for continuous incrementing counters like the
                 InOctets counter in a router. The CCCCOOOOUUUUNNNNTTTTEEEERRRR data
                 source assumes that the counter never decreases,
                 except when a counter overflows.  The update
                 function takes the overflow into account.  The
                 counter is stored as a per-second rate. When the
                 counter overflows, RRDtool checks if the
                 overflow happened at the 32bit or 64bit border
                 and acts accordingly by adding an appropriate
                 value to the result.

             DDDDEEEERRRRIIIIVVVVEEEE
                 will store the derivative of the line going from
                 the last to the current value of the data
                 source. This can be useful for gauges, for
                 example, to measure the rate of people entering
                 or leaving a room. Internally, derive works
                 exaclty like COUNTER but without overflow
                 checks. So if your counter does not reset at 32
                 or 64 bit you might want to use DERIVE and
                 combine it with a MIN value of 0.

             AAAABBBBSSSSOOOOLLLLUUUUTTTTEEEE
                 is for counters which get reset upon reading.
                 This is used for fast counters which tend to
                 overflow. So instead of reading them normally
                 you reset them after every read to make sure you
                 have a maximal time available before the next
                 overflow. Another usage is for things you count
                 like number of messages since the last update.

             _h_e_a_r_t_b_e_a_t defines the maximum number of seconds that
             may pass between two updates of this data source
             before the value of the data source is assumed to be
             _*_U_N_K_N_O_W_N_*.

             _m_i_n and _m_a_x are optional entries defining the
             expected range of the data supplied by this data
             source. If _m_i_n and/or _m_a_x are defined, any value
             outside the defined range will be regarded as
             _*_U_N_K_N_O_W_N_*. If you do not know or care about min and
             max, set them to U for unknown. Note that min and
             max always refer to the processed values of the DS.
             For a traffic-CCCCOOOOUUUUNNNNTTTTEEEERRRR type DS this would be the max
             and min data-rate expected from the device.

             _I_f _i_n_f_o_r_m_a_t_i_o_n _o_n _m_i_n_i_m_a_l_/_m_a_x_i_m_a_l _e_x_p_e_c_t_e_d _v_a_l_u_e_s _i_s
             _a_v_a_i_l_a_b_l_e_, _a_l_w_a_y_s _s_e_t _t_h_e _m_i_n _a_n_d_/_o_r _m_a_x _p_r_o_p_e_r_t_i_e_s_.
             _T_h_i_s _w_i_l_l _h_e_l_p _R_R_D_t_o_o_l _i_n _d_o_i_n_g _a _s_i_m_p_l_e _s_a_n_i_t_y
             _c_h_e_c_k _o_n _t_h_e _d_a_t_a _s_u_p_p_l_i_e_d _w_h_e_n _r_u_n_n_i_n_g _u_p_d_a_t_e_.




2001-02-20             Last change: 1.0.33                      2






rrdtool                                              RRDCREATE(1)



     RRRRRRRRAAAA::::_C_F::::_x_f_f::::_s_t_e_p_s::::_r_o_w_s
             The purpose of an RRRRRRRRDDDD is to store data in the round
             robin archives (RRRRRRRRAAAA). An archive consists of a
             number of data values from all the defined data-
             sources (DDDDSSSS) and is defined with an RRRRRRRRAAAA line.

             When data is entered into an RRRRRRRRDDDD, it is first fit
             into time slots of the length defined with the ----ssss
             option becoming a _p_r_i_m_a_r_y _d_a_t_a _p_o_i_n_t.

             The data is also consolidated with the consolidation
             function (_C_F) of the archive. The following
             consolidation functions are defined: AAAAVVVVEEEERRRRAAAAGGGGEEEE, MMMMIIIINNNN,
             MMMMAAAAXXXX, LLLLAAAASSSSTTTT.

             _x_f_f The xfiles factor defines what part of a
             consolidation interval may be made up from _*_U_N_K_N_O_W_N_*
             data while the consolidated value is still regarded
             as known.

             _s_t_e_p_s defines how many of these _p_r_i_m_a_r_y _d_a_t_a _p_o_i_n_t_s
             are used to build a _c_o_n_s_o_l_i_d_a_t_e_d _d_a_t_a _p_o_i_n_t which
             then goes into the archive.

             _r_o_w_s defines how many generations of data values are
             kept in an RRRRRRRRAAAA.

TTTThhhheeee HHHHEEEEAAAARRRRTTTTBBBBEEEEAAAATTTT aaaannnndddd tttthhhheeee SSSSTTTTEEEEPPPP
     Here is an explanation by Don Baarda on the inner workings
     of rrdtool.  It may help you to sort out why all this
     *UNKNOWN* data is popping up in your databases:

     RRD gets fed samples at arbitrary times. From these it
     builds Primary Data Points (PDPs) at exact times every
     "step" interval. The PDPs are then accumulated into RRAs.

     The "heartbeat" defines the maximum acceptable interval
     between samples. If the interval between samples is less
     than "heartbeat", then an average rate is calculated and
     applied for that interval. If the interval between samples
     is longer than "heartbeat", then that entire interval is
     considered "unknown". Note that there are other things that
     can make a sample interval "unknown", such as the rate
     exceeding limits, or even an "unknown" input sample.

     The known rates during a PDP's "step" interval are used to
     calculate an average rate for that PDP. Also, if the total
     "unknown" time during the "step" interval exceeds the
     "heartbeat", the entire PDP is marked as "unknown". This
     means that a mixture of known and "unknown" sample time in a
     single PDP "step" may or may not add up to enough "unknown"
     time to exceed "heartbeat" and hence mark the whole PDP



2001-02-20             Last change: 1.0.33                      3






rrdtool                                              RRDCREATE(1)



     "unknown". So "heartbeat" is not only the maximum acceptable
     interval between samples, but also the maximum acceptable
     amount of "unknown" time per PDP (obviously this is only
     significant if you have "heartbeat" less than "step").

     The "heartbeat" can be short (unusual) or long (typical)
     relative to the "step" interval between PDPs. A short
     "heartbeat" means you require multiple samples per PDP, and
     if you don't get them mark the PDP unknown. A long heartbeat
     can span multiple "steps", which means it is acceptable to
     have multiple PDPs calculated from a single sample. An
     extreme example of this might be a "step" of 5mins and a
     "heartbeat" of one day, in which case a single sample every
     day will result in all the PDPs for that entire day period
     being set to the same average rate. _-_- _D_o_n _B_a_a_r_d_a
     _<_d_o_n_._b_a_a_r_d_a_@_b_a_e_s_y_s_t_e_m_s_._c_o_m_>

HHHHOOOOWWWW TTTTOOOO MMMMEEEEAAAASSSSUUUURRRREEEE
     Here are a few hints on how to measure:

     Temperature
         Normally you have some type of meter you can read to get
         the temperature.  The temperature is not realy connected
         with a time. The only connection is that the temperature
         reading happened at a certain time. You can use the
         GGGGAAAAUUUUGGGGEEEE data source type for this. RRRtool will the record
         your reading together with the time.

     Mail Messages
         Assume you have a methode to count the number of
         messages transported by your mailserver in a certain
         amount of time, this give you data like '5 messages in
         the last 65 seconds'. If you look at the count of 5 like
         and AAAABBBBSSSSOOOOLLLLUUUUTTTTEEEE datatype you can simply update the rrd with
         the number 5 and the end time of your monitoring period.
         RRDtool will then record the number of messages per
         second. If at some later stage you want to know the
         number of messages transported in a day, you can get the
         average messages per second from RRDtool for the day in
         question and multiply this number with the number of
         seconds in a day. Because all math is run with Doubles,
         the precision should be acceptable.

     It's always a Rate
         RRDtool stores rates in amount/second for COUNTER,
         DERIVE and ABSOLUTE data.  When you plot the data, you
         will get on the y axis amount/second which you might be
         tempted to convert to absolute amount volume by
         multiplying by the delta-time between the points.
         RRDtool plots continuous data, and as such is not
         appropriate for plotting absolute volumes as for example
         "total bytes" sent and received in a router. What you



2001-02-20             Last change: 1.0.33                      4






rrdtool                                              RRDCREATE(1)



         probably want is plot rates that you can scale to for
         example bytes/hour or plot volumes with another tool
         that draws bar-plots, where the delta-time is clear on
         the plot for each point (such that when you read the
         graph you see for example GB on the y axis, days on the
         x axis and one bar for each day).

EEEEXXXXAAAAMMMMPPPPLLLLEEEE
     `rrdtool create temperature.rrd --step 300
     DS:temp:GAUGE:600:-273:5000 RRA:AVERAGE:0.5:1:1200
     RRA:MIN:0.5:12:2400 RRA:MAX:0.5:12:2400
     RRA:AVERAGE:0.5:12:2400'

     This sets up an RRRRRRRRDDDD called _t_e_m_p_e_r_a_t_u_r_e_._r_r_d which accepts one
     temperature value every 300 seconds. If no new data is
     supplied for more than 600 seconds, the temperature becomes
     _*_U_N_K_N_O_W_N_*.  The minimum acceptable value is -273 and the
     maximum is 5000.

     A few archives areas are also defined. The first stores the
     temperatures supplied for 100 hours (1200 * 300 seconds =
     100 hours). The second RRA stores the minimum temperature
     recorded over every hour (12 * 300 seconds = 1 hour), for
     100 days (2400 hours). The third and the fourth RRA's do the
     same with the for the maximum and average temperature,
     respectively.

AAAAUUUUTTTTHHHHOOOORRRR
     Tobias Oetiker <oetiker@ee.ethz.ch>


























2001-02-20             Last change: 1.0.33                      5